Cavity barrier
Approved document B, Fire Safety, Volume 2, Buildings other than dwellinghouses (2019 edition), defines a cavity as:
A space enclosed by elements of a building (including a suspended ceiling) or contained within an element, but that is not a room, cupboard, circulation space, protected shaft, or space within a flue, chute, duct, pipe or conduit.
And a cavity barrier as:
A construction within a cavity, other than a smoke curtain, to perform either of the following functions.
- Close a cavity to stop smoke or flame entering.
- Restrict the movement of smoke or flame within a cavity
As most buildings contain a multitude of concealed cavities and voids within walls, floors, ceilings and roofs, effective cavity barriers are essential to restrict the spread of smoke or flames. If there is a fire, the intumescent material which makes up the barrier will expand, sealing off the gaps.
Cavity barriers are typically pieces of fire-stopping material which are fitted within building cavities - horizontally at each floor, and vertically at each party wall. This assists with fire compartmentation.
The location of each cavity will determine the appropriate maximum distance between the barriers, as well as the class of surface which is exposed within the cavity. The performance of cavity barriers much be maintained throughout the lifecycle of a building, with consideration given to any building movement due to subsidence, shrinkage, and so on.
Cavity barriers must be fitted tightly to rigid construction, or suitably fire-stopped at a junction between itself and construction to which it cannot be fitted so tightly (e.g. slates, tiles, sheeting, etc.). The likelihood of the fixings failing in the event of a fire should be carefully considered. Services that may run through a barrier should be fire-stopped using appropriate materials.
PAS 9980:2022, Fire risk appraisal of external wall construction and cladding of existing blocks of flats – Code of practice, published by BSI Standards Limited in 2022, defines a cavity barrier as a: ‘product used to close or separate a concealed space, the purpose of which is to restrict the spread of smoke and/or fire.’
It defines a closed state cavity barrier as a: ‘nonloadbearing element designed to provide fire separation within or at the edges of a concealed space (cavity) by forming a tight seal (possibly under compression) between the inner and outer surfaces of the cavity.’
And an open state cavity barrier as a: ‘non-loadbearing element designed to provide fire separation in a concealed space (cavity), which is open to allow ventilation and drainage in the cold state, but which closes when exposed to a developing fire.’
[edit] Related articles on Designing Buildings
Featured articles and news
The continued ISG fall out, where to go?
Support for ISG contractors, companies and employees.
New HES national centre for traditional building retrofit
Announced as HES publishes survey results which reveal strong support for retrofit.
Retrofit of Buildings, a CIOB Technical Publication
Expected to become one of the largest activities in the global construction industry.
The ECA industry focus video channel
Keeping update with the industry session by session.
Over 25 recorded informations sessions freely available.
AT Awards 2024 ceremony East London October 25th.
Revisiting the AT community at the 2023 awards evening.
The Community Housing Fund and built affordable homes
CLTN reviews the impact of the Fund and calls for extension.
The grading system of the Regulator for Social Housing
A background, an explanation and ten recent enforcements.
Construction, repair and maintenance. Book review.
Putting new life into a city with a 1900 year history.
BSRIA Briefing 2024: Sustainable Futures speakers
Redefining Retrofit for Net Zero Living 22 Nov.
Wall of support for post-Grenfell regulation of electricians
Call for a shake-up of the construction industry highlighted on radio.
Digital sustainability through future AEC tools
Bringing together industry and academia to meet challenges.
Skills gap for net zero highlighted to Minister for Industry
ECA convenes roundtable discussion at Portcullis House.
Evidencing Net Zero with the new UK buildings standard
Pilot version with detailed excel proforma out now!
Scottish Building Safety Levy, in consultation
From direct remediation and the RPDT, to the costs and alternatives.
Waves of warmer homes grants for the rental sector
Boosting energy efficiency standards for all rented homes.
A refocus of the National Planning Policy Framework
Key terms described in brief, as the consultation closes the evening of the 24th.
Fortified farmhouses of the unruly 16th-and 17th-century borders.